Research Article

Parameter Optimisation of Power Regeneration on the Hydraulic Electric Regenerative Shock Absorber System

Table 9

Summary of simulation tests.

Test no.Shaft speed (rpm)Hydraulic motor pressure (bar)Input power (W)Regenerated power (W)Regeneration efficiency

Test 11651.392846.4087781.801417.50.53402
Test 21340.056919.8006342.7223223.90.65334
Test 31175.669611.384204.1776139.80.68482
Test 41055.3147.317137.176894.20.68667
Test 5810.63288.8879101.527766.430.65427
Test 6988.523710.621117.177382.610.70496
Test 7665.281411.886129.559966.650.50674
Test 8727.51679.487965.955765.960.62528
Test 9461.29823.567630.072717.980.59788
Test 10410.77133.563829.608317.060.57626
Test 11648.102111.733781.890352.310.63877
Test 12531.538812.191884.793343.180.50923
Test 13251.69252.940415.49957.8880.5089
Test 14284.29865.755626.309512.350.46945
Test 15312.03712.736614.59378.2280.56378
Test 16388.84165.226724.238815.280.63042