Research Article
Vibration Failure Analysis and Countermeasures of the Inlet Pipelines at a Gas Compressor Station
Table 2
Boundary conditions of the inlet pipeline modification models for CFD analysis.
| Position | Model A | Model B | Model C | Boundary condition | Value | Boundary condition | Value | Boundary condition | Value |
| Inlet1 | Pressure inlet | 4.2 MPa | Pressure inlet | 4.2 MPa | Pressure inlet | 4.2 MPa | Inlet2 | Wall | — | Wall | — | Pressure inlet | 4.2 MPa | No. 1 | Velocity outlet | 0.89 m/s | Velocity outlet | 0.89 m/s | Velocity outlet | 0.89 m/s | No. 2 | Velocity outlet | 0.89 m/s | Velocity outlet | 0.89 m/s | Velocity outlet | 0.89 m/s | No. 3 | Velocity outlet | 0.89 m/s | Velocity outlet | 0.89 m/s | Velocity outlet | 0.89 m/s | No. 4 | Wall | — | Wall | — | Wall | — |
|
|
Velocity 0.89 m/s is converted by 64 × 104 m3/d based on the gas equation of state and the diameter of pipe.
|