Research Article

A New Identification Method for Bolt Looseness in Wind Turbine Towers

Table 3

Vibration test conditions of the wind turbine towers.

Experiment IDContent of working conditionTest environment conditionTightening condition of flange plate

1Vibration test when tower is in an inactive stateWind speed is less than 5 m/sBefore tightening
2Vibration test when tower is in an inactive stateWind speed is 18∼2 m/sBefore tightening
3Vibration test when tower is in an active stateWind speed is 7∼10 m/sBefore tightening
4Vibration test when tower is in an active stateWind speed is 18∼24 m/sBefore tightening
5Vibration test when tower is in an inactive stateWind speed is 18∼22 m/sAfter tightening
6Vibration test when tower is in an active stateWind speed is 18∼24 m/sAfter tightening

Note. Flange tightening refers to only retightening of each bolt on the flange by the torque method.