Research Article

Dynamic Compressive and Tensile Characteristics of a New Type of Ultra-High-Molecular Weight Polyethylene (UHMWPE) and Polyvinyl Alcohol (PVA) Fibers Reinforced Concrete

Table 7

Performance parameters of fiber concrete of different groups under different strain rates.

Group no.Air pressure (MPa)Strain rate (sāˆ’1)Dynamic tensile strength (MPa)Static compressive strength (MPa)DIF

00.207.848.213.842.14
0.2512.4311.132.90
0.3018.3213.543.53
0.3524.2515.434.02
0.4029.6717.054.14

P-0.60.207.668.784.012.19
0.2512.2411.922.97
0.3017.8314.523.62
0.3523.7616.584.13
0.4029.2718.374.58

U-0.60.207.428.974.062.21
0.2512.0812.183.00
0.3017.5814.843.66
0.3523.4916.954.17
0.4028.9618.774.62

P-1.20.207.269.174.092.24
0.2511.9512.463.05
0.3017.4215.193.71
0.3523.2017.364.24
0.4028.7219.244.70

U-1.20.207.159.444.142.28
0.2511.8312.823.10
0.3017.2715.633.78
0.3522.9817.864.31
0.4028.4319.784.78

P-1.80.207.099.524.162.29
0.2511.7112.923.11
0.3017.1315.733.78
0.3522.8217.844.29
0.4028.2119.694.73

U-1.80.206.979.694.202.31
0.2511.4813.183.14
0.3016.7416.103.83
0.3522.3718.394.38
0.4027.6220.384.85

P-2.40.206.899.614.212.28
0.2511.3613.073.10
0.3016.5815.953.79
0.3522.1318.244.33
0.4027.3520.194.80

U-2.40.206.759.874.262.32
0.2511.2713.423.15
0.3016.3416.383.85
0.3521.9818.714.39
0.4027.0620.704.86