Research Article
Behaviors of Thin-Walled Cylindrical Shell Storage Tank under Blast Impacts
Table 6
Deformation energy of oil storage tank with fixed constraint (unit: MJ).
| Structure | 25% filled (Hliquid = 5.4 m) | 50% filled (Hliquid = 11 m) | 75% filled (Hliquid = 16 m) | Deformation energy (EPT) | Percentage | Deformation energy (EPT) | Percentage | Deformation energy (EPT) | Percentage |
| Bottom plate | 0 | 0 | 0 | 0 | 0 | 0 | 1st wall | 23.68 | 12.3 | 9.41 | 7 | 0.14 | 0.18 | 2nd wall | 8.14 | 4.2 | 5.21 | 3.9 | 0.93 | 1.2 | 3rd wall | 11.07 | 5.8 | 2.98 | 2.2 | 0.76 | 0.99 | 4th wall | 9.84 | 5.1 | 4.61 | 3.4 | 0.89 | 1.2 | 5th wall | 15.5 | 8.1 | 10.54 | 7.9 | 2.17 | 2.8 | 6th wall | 24.16 | 12.6 | 16.27 | 12.1 | 4.7 | 6.1 | 7th wall | 13.75 | 7.2 | 12.55 | 9.4 | 10.06 | 13.1 | 8th wall | 19.39 | 10.1 | 16.11 | 12 | 18.92 | 24.6 | Wind girders | 66.33 | 34.6 | 56.44 | 42.1 | 38.37 | 49.9 | Total energy | 191.85 | 134.22 | 76.95 |
|
|