Research Article

Fusion of Vibration and Current Signatures for the Fault Diagnosis of Induction Machines

Table 7

Classification accuracy of the current signal by different SVM kernels (%).

SVM kernelNormalBRBMISIRFORFAverage

Linear77.7810072.2261.1161.1174.44
Polynomial61.1110033.3338.8955.5657.78
Gaussian61.1110033.3355.5666.6763.33