Research Article

Personnel Casualty Assessment for Explosion in the Subway Platform

Table 4

Casualty distance of personnel for explosion in subway platform.

Subway structureLocation of explosion sourceTNT equivalent (kg)Death distance (m)Distance of serious injury (m)Distance of light injury (m)

No shield doorCenter of the platform51.4145.38539.000
104.2436.80060.351
205.00011.00060.351
406.08312.00060.351
Edge of the platform406.57515.07461.392
Entrance to the stairs408.24617.00030.696
Shield doorHalf-heightCenter of the platform408.84512.77660.351
Full-height and semiclosed9.55213.15260.351
Full-height and fully closed9.55214.56060.351