Research Article

Fault Diagnosis of Variable Load Bearing Based on Quantum Chaotic Fruit Fly VMD and Variational RVM

Table 2

Optimal search results.

Load0 hp1 hp2 hp

The calculated value of the fault frequency (Hz)119.39118.01116.61
Fault measured value (Hz)119.4117.9116.5
[α, K][2000, 6][1600, 6][1400, 8]
Optimal IMFIMF4IMF4IMF6
Normalized center frequency0.49470.42240.3644
LMMSE0.32280.32310.3275