Research Article

Fault Diagnosis of Piezoelectric Sensor Patches for Vibration Control Based on Multifeature Fusion and Improved SVM

Table 1

SVD values of the IMF components of the three types of piezoelectric patches.

SVD values of the first 5 IMF components
CategoryV1V2V3V4V5

Normal79.985.4040.28440.25110.1096
85.036.2790.90190.09150.0505
88.436.8851.3030.08360.0723
88.927.1651.4520.26900.1587
85.697.1631.2380.11580.0588

Broken71.863.9433.2461.0880.6276
67.293.1361.6010.24290.1181
71.773.2722.6890.38770.3001
71.563.4892.9180.28700.2517
74.153.2682.9140.57060.4317

Degummed1.2780.10990.03370.016310.009516
1.2330.10170.02310.013570.009732
1.2320.09740.01450.011440.006103
1.2690.10030.04840.021600.01327
1.2820.09830.01260.0083940.005366