Research Article
Adaptive Damping of a Double-Beam Structure Based on Magnetorheological Elastomer
Table 2
Fundamental parameters of the test rig.
| Parameter | Value |
| Dimensions of a single beam | , , mm | Position of distance rolls from the support | , mm | Position of sensors from the support | , , mm | Dimensions of MRE blocks | , , mm | Resolution/response time of sensors | 0.01 mm/ | Sampling of the measurement card | 1000 Hz | Initial deflection of the beam at sensor | 32 mm |
|
|