Fundamental parameters of the test rig.

ParameterValue

Dimensions of a single beam, ,  mm
Position of distance rolls from the support,  mm
Position of sensors from the support, ,  mm
Dimensions of MRE blocks, ,  mm
Resolution/response time of sensors0.01 mm/
Sampling of the measurement card1000 Hz
Initial deflection of the beam at sensor 32 mm