Research Article

Research on Dynamic Load Identification Based on Explicit Wilson-θ and Improved Regularization Algorithm

Table 2

Regularization parameters and relative accumulation errors of harmonic load.

Sampling frequency (Hz)Noise level (%)Regularization parameterError (%)
IRATikhonovIRATikhonov

50001e 161e 170.9516613.896035
101e 142e 153.0875545.168342
205e 132e 155.0938649.398055
301e 123e 157.48908711.361723

100001e 161e 170.1661750.20726
101e 142e 152.1191254.458908
205e 136e 153.7975097.188128
301e 123e 155.18287510.441882

200001e 141e 160.0998460.316657
101e 131e 152.028053.813177
205e 136e 152.5826565.145480
304e 125e 153.3402858.215345