Research Article

Strain Monitoring of Combustible Gas Implosion Test Based on Fiber Bragg Grating

Table 5

Comparison of the overpressure strain results of the four tests.

NumberInitial strain of grating (average of the first 100 data) (με)Minimum compressive strain (με)Time from the vent opening to the full extent (ms)

First test−2.212−5.907600
Second test12.2261.969161
Third test16.42514.976140
Fourth test17.728−30.453109