Storeys where the five dampers fail under the ANE with different PVAs.

DampersPVA (cm/s)
305080100130150160

BRBStorey 5, 4, 3, 2, 1Storey 5, 4, 3, 2, 1Storey 5, 4, 3, 2, 1, 6Storey 5, 4, 3, 2, 1, 6Storey 5, 4, 3, 2, 1, 6
FDStorey 2, 1, 3, 4, 5Storey 1, 2, 3, 4, 5Storey 1, 2, 3, 4, 5, 6Storey 1, 2, 3, 4, 5, 6Storey 1, 2, 3, 4, 5, 6
SCDStorey 5, 4, 3, 2, 1Storey 5, 4, 3, 2, 1Storey 3, 4, 2, 5, 6, 1, 7, 8Storey 3, 2, 4, 5, 6, 1, 7, 8Storey 3, 2, 4, 5, 6, 1, 7, 8
VD