Research Article

Linkage Analysis between Solid-Fluid Coupling and the Strength Reduction Method for Karst Cave Water Inrush in Mines

Table 3

Safety thickness of water-proof rock pillar setting in the Maokou limestone for the Qiyi coal mine.

Kars water pressure (MPa)Blasthole depth h1 (m)Blasting disturbance depth h2 (m)Calculation safety thickness of rock pillar h3 (m)Safety thickness of water-proof rock pillar setting (H/m)

1.02.51.55.189.18
2.02.51.55.739.73
3.02.51.56.8910.89
4.02.51.57.9811.98
5.02.51.57.9813.32