Research Article

[Retracted] Complex Behavior of Droplet Transfer and Spreading in Cold Metal Transfer

Table 2

Physical parameter values used for calculations.

Properties (units)Values

Density (kg·m−3)2700
Area of the electrode (mm2)1.44
Arc voltage (V)18
Arc heating parameter (kg/As)7.992 × 10−11
Joule heating parameter (kg/mA2s)1.252 × 10−11
Surface tension (N/m)1.2