Research Article

Train-Induced Fluctuating Pressure and Resultant Dynamic Response of Semienclosed Sound Barriers

Table 3

Peak CP on monitored section of SESB.

Working conditionPeak positive CP on C4Peak negative CP on C2Peak negative CP on C1

No top plates0.138−0.115−0.053
Only curve plate0.140−0.116−0.054
1 top plate0.141−0.117−0.061
2 top plates0.143−0.119−0.068
3 top plates0.144−0.121−0.0712
4 top plates0.145−0.122−0.0738
5 top plates0.146−0.124−0.0759