Research Article
Analysis of Effective Operation Performance of Wireless Control Downhole Choke
Table 3
Throttling pressure drop at different throttling openings.
| Production | Opening (°) | Pressure drop (MPa) | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 |
| 50,000 m3 | 0.43 | 0.1 | 0.04 | 0.025 | 0.017 | 0.013 | 0.011 | 0.01 | 100,000 m3 | 1.7 | 0.4 | 0.168 | 0.09 | 0.071 | 0.05 | 0.044 | 0.042 | 150,000 m3 | 3.82 | 0.91 | 0.38 | 0.212 | 0.14 | 0.108 | 0.095 | 0.092 | 200,000 m3 | 6.77 | 1.61 | 0.68 | 0.372 | 0.246 | 0.188 | 0.169 | 0.16 |
|
|