Peak top floor displacement and acceleration responses of dissimilar connected buildings for unequal storey height under historical earthquake ground motions.

FrameEarthquakePeak top floor displacement, xn (cm)Peak top floor acceleration, n ()
UABCUABC

5-10 MRF-MRFImperial Valley, 194011.496.436.528.011.510.890.960.92
Loma Prieta, 198926.6712.869.0911.323.581.651.361.85
Northridge, 199416.9610.4311.7312.352.682.062.592.08
Kobe, 199512.1010.4710.0111.201.721.691.651.58

15-20 MRF-MRFImperial Valley, 194016.7710.7914.8215.200.860.650.610.50
Loma Prieta, 198977.6959.5266.8368.431.901.531.691.69
Northridge, 199486.9167.8870.7873.002.361.241.451.35
Kobe, 199525.1922.8223.1323.211.261.141.151.16

5-10 BF-BFImperial Valley, 19403.362.391.862.061.440.890.930.90
Loma Prieta, 19897.153.874.104.372.651.081.141.34
Northridge, 199410.617.398.468.144.002.442.722.67
Kobe, 19958.973.844.644.432.941.431.671.56

15-20 BF-BFImperial Valley, 194019.746.199.1110.671.250.850.671.02
Loma Prieta, 198934.9927.8532.1132.972.581.581.811.78
Northridge, 199428.0125.9426.9426.802.001.861.881.90
Kobe, 199550.3331.9634.8836.202.701.812.011.98