Research Article

Rolling Bearing Fault Diagnosis Based on Sensitive Feature Transfer Learning and Local Maximum Margin Criterion under Variable Working Condition

Table 11

Testing accuracies obtained by OFS-TSFRS-SVM.

sfnDTCWPTWPT
Case 1 testing accuracy (%)Case 2 testing accuracy (%)Case 3 testing accuracy (%)Case 4 testing accuracy (%)Case 1 testing accuracy (%)Case 2 testing accuracy (%)Case 3 testing accuracy (%)Case 4 testing accuracy (%)

1093.5482.7094.5872.0896.0452.9275.6353.13
2095.0088.5494.1768.3398.9666.0495.8389.58
3094.3886.4693.5469.3898.9666.0497.2982.08
4094.3886.4693.7569.3895.6379.7997.9299.38
5096.8886.2596.0473.1396.4684.1799.3894.38
7097.7186.0496.2573.9695.2159.5898.5494.38
9097.9283.1396.6775.0095.2159.5898.9694.79
12098.7581.8897.0879.3898.1367.0897.5074.79
14098.7583.7597.9277.9297.2969.7997.9274.58
16098.7583.9697.9277.9297.7170.4298.1377.29
18098.9683.5498.1378.9696.6774.7996.8876.46