Dynamic Model for Axial Motion of Horizontal Pelton Turbine and Validation in Actual Failure Case
Table 3
Model prediction and experimental measurements, Case I.
| Power rate in MW | Axial position of rotor in mm | Model prediction | Experimental measurement | Difference |
| 0 | Maximum | 0.45 | 0.45 | 0.00 | Minimum | −0.45 | −0.45 | 0.00 |
| 2 | Maximum | −0.27 | −0.28 | 0.01 | Minimum | −0.29 | −0.28 | 0.01 |
| 4 | Maximum | −0.25 | −0.26 | 0.01 | Minimum | −0.26 | −0.26 | 0.00 |
| 6 | Maximum | −0.22 | −0.23 | 0.01 | Minimum | −0.23 | −0.23 | 0.00 |
| 8 | Maximum | −0.19 | −0.20 | 0.01 | Minimum | −0.20 | −0.20 | 0.00 |
| 10 | Maximum | −0.17 | −0.17 | 0.00 | Minimum | −0.18 | −0.17 | 0.01 |
|
|