Research Article

Probabilistic Assessment of Damage from Same Shock Response Spectra due to Variations in Damping

Table 3

Synthesis of four waveforms with the same SRS.

Frequency (Hz)100200400650950

Trial 1: proportional damping to get the same decay

Damping0.075000.037500.018750.011540.00750

Amplitude1010101010

Trial 2: X3 damping of Trial 1 at 650 and 950 Hz

Damping0.0750.03750.018750.034620.0225

Amplitude10101013.613.2

Trial 3: X4 damping of Trial 1 at 650 and 950 Hz

Damping0.0750.03750.018750.046160.03

Amplitude10101015.414.7

Trial 4: X2 damping of Trial 1 at 100 and 200 Hz

Damping0.150.0750.018750.011540.0075

Amplitude1414101010