Research Article
Seismic Fragility Analysis of Bridge Group Pile Foundations considering Fluid-Pile-Soil Interaction
Table 7
The displacement of pier top node comparisons (unit: m).
| Model | Excitations | Without FSI | Considering FSI | d = 10 m | d = 20 m | d = 40 m |
| Model A | FF1 | 2.86 | 2.85 | 2.82 | 2.82 | FF2 | 0.43 | 0.43 | 0.43 | 0.43 | FF3 | 2.10 | 2.11 | 2.13 | 2.22 | FF4 | 1.88 | 1.93 | 1.98 | 2.10 |