Research Article

Fault Diagnosis of Hydraulic Pumps Using PSO-VMD and Refined Composite Multiscale Fluctuation Dispersion Entropy

Table 6

The accuracy of different methods.

Different methodsClassification accuracy (%)CPU time (s)
MaxMinMean

PSO-VMD and RCMFDE100100100204.01
PSO-VMD and CMFDE10098.7599.78205.88
PSO-VMD and MFDE10091.2596.7539.12
PSO-VMD and MDE98.7592.5096.5839.29
PSO-VMD and MFE98.7592.5095.73843.11
PSO-VMD and MSE97.587.593.63453.50