Research Article

Fault Diagnosis of Hydraulic Pumps Using PSO-VMD and Refined Composite Multiscale Fluctuation Dispersion Entropy

Table 7

The accuracy of different methods without PSO-VMD.

Different methodsClassification accuracy (%)
MaxMinMean

RCMFDE98.7591.2595.33
CMFDE97.59095.25
MFDE97.59092.90
MDE959092.53
MFE93.7586.2590.03
MSE93.7583.7589.25