Research Article

Multidimensional System Identification and Active Vibration Control of a Piezoelectric-Based Sting System Used in Wind Tunnel

Table 5

Different damping ratios.

Control stateDamping ratio in pitch direction (%)Damping ratio in yaw direction (%)

Without control0. 110.15
With control,  = 0.200.640.65
With control,  = 0.150.830.78
With control,  = 0.100.920.91
With control,  = 0.051.041.06