Plate load test results of loess before and after DC with different reinforcement methods.

Types of loessI0μd0 (m)γ (kN/m3) (kPa)s (mm)E0 (MPa)

Undisturbed loessQ20.7850.380.620.0360–4505.8–7.723.5
Q3(Zone-1)0.7850.350.818.587.511.8–13.23.9
Q3 (Zone-3)0.7850.350.818.8120–13510.7–11.56.5

Compacted loessDC (2000 kN·m)0.8860.351.021.0310–4206.32–9.9630.0
DC (3000 kN·m)0.8860.351.021.0320–4508.97–10.035.0
DC (6000 kN·m)0.8860.351.021.0360–4206.78–8.3639.0
VC + DC (2000 kN·m)0.8860.351.021.0350–3609.69–10.028.0
VC + DC (3000 kN·m)0.8860.351.021.0360–4009.45–10.028.8
VSGP0.7850.350.523.0336–5009.2–10.013.2
PSCP0.7850.270.521.0240–41010.0–15.016.0

Note. I0 is the shape factor of the rigid bearing plate; μ is Poisson’s ratio of soil; d0 is the diameter or edge length of the rigid bearing plate; γ is the unit weight of soil; s is the settlement of the rigid bearing plate; is the bearing capacity value; E0 is the deformation modulus.