Research Article
Novel Condition Monitoring Method for Wind Turbines Based on the Adaptive Multivariate Control Charts and SCADA Data
Table 3
Anomaly information for the wind turbine unit during the period from 12/1/2015 to 6/1/2016.
| Anomaly no. | Anomaly description | Monitored period | Number of data points | Time of alarm log |
| A | Generator brush worn | 12/3/2015 19 : 10–12/7/2015 6 : 30 | 500 | 12/6/2015 20 : 30 (alarm log: point no. 440) |
| B | Gearbox running hot in low generator stage | 2/1/2016 00 : 00–2/4/2016 11 : 10 | 500 | 2/3/2016 22 : 10 (alarm log: point no. 421) |