Research Article
Study on Concrete Pier Impact Performance after Implementing Equal Cross-Section Stainless Steel with Protection from Closed-Cell Aluminum Foam
Table 8
Test results of the peak strain and stress of the No. 4 reinforcement.
| Height of drop hammer (m) | Average impact velocity (m/s) | 1st group | 2nd group | No. 4 peak (με) | No. 4 stress (MPa) | No. 4 peak (με) | No. 4 stress (MPa) | S1-16 | Z2-16 | S1-16 | Z2-16 | S1-20 | Z2-20 | S1-20 | Z2-20 |
| 2 | 0.72 | 543.38 | 797.15 | 104.87 | 159.43 | 203.14 | 405.6 | 39.21 | 81.12 | 4 | 1.10 | 864.53 | 1159.78 | 166.85 | 231.96 | 460.43 | 735.43 | 78.28 | 147.09 | 6 | 1.42 | 1564.35 | 1716.23 | 325.08 | 343.25 | 550.25 | 988.73 | 106.20 | 197.75 | 8 | 1.67 | 2314.26 | 2536.65 | 465.95 | — | 652.21 | 1123.45 | 125.88 | 224.69 | 10 | 1.84 | 2543.88 | 2872.25 | 516.06 | — | 958.06 | 1473.18 | 184.91 | 294.64 | 12 | 2.08 | 2812.34 | 2946.47 | 546.64 | — | 1011.43 | 1896.14 | 195.21 | 379.23 |
|
|