Research Article

Bearing Fault Diagnosis Based on Multilayer Domain Adaptation

Table 4

Experimental results of different parameter settings.

Transfer taskMLDA-1 (%)MLDA-4 (%)MLDA-SK (%)MLDA (%)

0-190.7995.2192.7699.52
0-284.0780.2184.0099.24
0-374.3286.9985.6397.52
1-094.0796.9694.5099.81
1-291.6495.5794.9199.60
1-387.9392.5391.3499.40
2-080.9889.8784.2399.65
2-188.3198.0794.0699.63
2-394.8598.3286.6498.89
3-064.1976.6375.3398.65
3-182.4983.0389.5898.68
3-279.7094.8588.0399.07