Research Article

Vibration Test and Shock Absorption of Coal Crusher Chambers in Thermal Power Plants (II): Numerical Analysis

Table 10

Positions of spring vibration isolators in model.

Spring vibration isolatorsOriginal modelThe model with an eccentricity of 5%The model with an eccentricity of 10%
XYXYXY

1000000
20.4800000
30.9600.4800.480
41.4400.9600.960
51.9201.4401.440
62.401.9201.920
703.58503.58503.585
80.483.5850.483.58503.585
90.963.5850.963.5850.483.585
101.443.5851.443.5850.963.585
111.923.5851.923.5851.443.585
122.43.5852.43.5851.923.585
1304.33504.33504.335
1405.08505.08505.085
1506.08506.08506.085
1607.08507.08507.085
172.44.3352.44.3352.44.335
182.45.0852.45.0852.45.085
192.46.0852.46.0852.46.085
202.47.0852.47.0852.47.085
Center of rigidity1.21.080.96
Center of mass1.21.21.2
Relative error0%5%10%