Research Article

Vibration Test and Shock Absorption of Coal Crusher Chambers in Thermal Power Plants (II): Numerical Analysis

Table 14

Dynamic coefficients of points under each vibration-isolation efficiency.

LocationDynamic displacement (μm)Static displacement (μm)Dynamic coefficients
90%80%70%60%90%80%70%60%90%80%70%60%

L12.374.676.889.011.783.575.357.141.331.311.291.26
L21.092.153.144.091.082.153.234.311.011.000.970.95
L32.474.887.209.481.973.945.927.891.251.241.221.20
L41.132.223.274.301.212.423.634.840.930.920.900.89
L51.152.273.364.451.312.613.925.230.880.870.860.85
L61.152.273.384.531.362.724.085.440.850.830.830.83
L71.122.233.334.501.362.734.095.450.820.820.810.83
L81.072.133.204.351.322.633.955.260.810.810.810.83
L92.394.747.099.492.144.276.418.541.121.111.111.11
L102.494.947.369.832.214.416.618.811.131.121.121.12
L112.555.037.489.932.194.386.578.761.161.151.141.13
L122.545.007.419.802.114.226.348.451.201.181.171.16