Research Article
Noise Reduction for Modal Parameter Identification of the Measured FRFs Using the Modal Peak-Based Hankel-SVD Method
Table 1
Modal parameters of the noised FRF signal.
| Mode | Modal frequency (Hz) (original) | Modal frequency (Hz) (noised) | Frequency difference (Hz) | Damping factor (original) | Damping factor (noised) | Damping factor difference (%) |
| 1 | 63.67794 | 72.34572 | 8.66778 | 0.000674 | ā0.00682 | 1111.957 | 2 | 399.3322 | 398.8602 | 0.472005 | 0.000295 | 0.000769 | 160.5308 | 3 | 428.0756 | 428.581 | 0.505418 | 0.000667 | 0.000515 | 22.80982 | 4 | 1119.442 | 1119.783 | 0.340427 | 0.000866 | 0.000991 | 14.50155 | 5 | 1334.573 | 1328.813 | 5.760097 | 0.000943 | 0.000941 | 0.250468 | 6 | 2195.12 | 2195.789 | 0.66933 | 0.001474 | 0.00135 | 8.443071 | 7 | 2381.407 | 2381.004 | 0.402907 | 0.001588 | 0.001627 | 2.482244 |
|
|