Research Article
Noise Reduction for Modal Parameter Identification of the Measured FRFs Using the Modal Peak-Based Hankel-SVD Method
Table 2
Modal parameters of the noised and noise-reduced FRF signals.
| Mode | Modal frequency (Hz) (original) | Modal frequency (Hz) (denoised) | Frequency difference (Hz) | Damping factor (original) | Damping factor (denoised) | Damping factor difference (%) |
| 1 | 63.6779 | 63.61561 | 0.062331 | 0.000674 | 0.001091 | 61.78994 | 2 | 399.332 | 399.2953 | 0.036889 | 0.000295 | 0.000393 | 32.93652 | 3 | 428.076 | 428.108 | 0.032425 | 0.000667 | 0.000553 | 17.06583 | 4 | 1119.44 | 1119.429 | 0.013394 | 0.000866 | 0.000788 | 8.984838 | 5 | 1334.57 | 1334.775 | 0.202722 | 0.000943 | 0.000892 | 5.423373 | 6 | 2195.12 | 2195.505 | 0.385319 | 0.001474 | 0.001456 | 1.267132 | 7 | 2381.41 | 2380.844 | 0.562656 | 0.001588 | 0.001563 | 1.541009 |
|
|