Research Article

Dynamic Response of Parallel Overlapped Tunnel under Seismic Loading by Shaking Table Tests

Table 5

Acceleration energy ratio of the crown and invert under different amplitude seismic waves.

Monitoring point0.20.40.6
A3A4A5A6A3A4A5A6A3A4A5A6

Energy ratio of each frequency band (%)E179.7180.6089.9477.3378.1048.1487.1689.9674.3348.9380.5283.56
E216.9414.106.6718.5819.6440.7010.288.5522.8340.7316.4714.55
E30.650.790.671.510.671.360.600.550.811.260.780.65
E41.532.791.081.221.288.771.450.521.587.991.780.83
E50.060.080.070.060.020.050.020.010.020.050.020.02
E60.430.600.570.130.050.230.050.040.070.240.060.04
E70.290.430.540.990.180.330.350.330.230.430.290.27
E80.390.610.560.170.070.420.100.050.120.370.090.06