Research Article
Pressure Load Characteristics of Explosions in an Adjacent Chamber
Table 3
Comparison of experimental and calculated values of quasistatic peak pressure.
| Simulated chamber | Experimental value (MPa) | Calculated value (MPa) | Relative error (%) |
| 1 | 0.88 | 0.95 | +7.95 | Main chamber of 2 | 0.55 | 0.58 | +5.45 | Adjacent chamber of 2 | 0.45 | 0.58 | +28.9 |
|
|