Research Article

Fault Diagnosis of Subway Traction Motor Bearing Based on Information Fusion under Variable Working Conditions

Table 3

Accuracy rate of single condition fault diagnosis.

No.Training set speed (rpm)Training set load (kN)Test set speed (rpm)Test set load (kN)Diagnostic accuracy (%)
Acoustic emissionVibrationComprehensive

18005, 7800994.4495.83100
28005, 9800783.33100100
38007, 9800566.6770.8391.67
48005, 7, 98005, 7, 9100100100
516005, 71600983.33100100
616005, 91600795.83100100
716007, 91600595.83100100
816005, 7, 916005, 7, 995.83100100
924005, 724009100100100
1024005, 924007100100100
1124007, 92400591.67100100
1224005, 7, 924005, 7, 9100100100
13800, 160052400545.8379.17100
14800, 240051600554.1783.33100
151600, 24005800525.0041.6750.00
16800, 1600, 24005800, 1600, 2400594.44100100
17800, 160072400754.1783.3383.33
18800, 240071600762.5083.3387.50
191600, 24007800733.3350.0075.00
20800, 1600, 24007800, 1600, 2400777.78100100.0
21800, 160092400937.5079.1783.33
22800, 240091600975.00100100
231600, 2400980092558.3329.17
24800, 1600, 24009800, 1600, 2400966.7088.89100