Research Article

Seismic Fragility Assessment of RC Plan-Asymmetric Wall-Frame Structures Based on the Enhanced Damage Model

Table 4

Comparison of damage factors on the first story.

PGAShear-wall damage factor (Du damage model)Story damage factor (Du damage model)Story damage factor (II damage model)

0.20.050.040.049
0.40.210.190.205
0.60.670.590.667