Research Article

Research on Multiobjective Optimization of Bulb Tubular Turbine Based on Orthogonal Test

Table 5

Comparison of numerical simulation calculation and test results under different working conditions.

Working conditionn11/r/minQ11/m3/sGuide vane opening/°Blade angle/°Effectivenessη/%
CalculatedTest value

1179.01.3848.015.080.5378.12
2169.81.6552.020.384.8782.50
3170.62.0156.125.390.7988.36
4190.02.8468.033.589.9287.25
5180.03.2071.538.685.5683.01
6187.63.5273.739.881.7179.37