Research Article

Robust Assignment of Natural Frequencies and Antiresonances in Vibrating Systems through Dynamic Structural Modification

Table 13

Test-case 3: original and modified systems: percentage variation of the third natural frequency.

Percentual variations (%) [Δk1; Δk2; Δk3]Original system Δωp,3 (%)Mod. robust (proposed method) Δωp,3 (%)

[−25; −25; −25]−10.92−5.62
[+25; −25; −25]−9.11−4.69
[−25; +25; −25]0.42−0.15
[+25; +25; −25]3.701.44
[−25; −25; +25]−9.11−4.69
[+25; −25; +25]−6.78−3.35
[−25; +25; +25]3.701.44
[+25; +25; +25]9.364.54
max (Δωp,3(%))9.364.54
min (Δωp,3(%))−10.92−5.62