Research Article
Robust Assignment of Natural Frequencies and Antiresonances in Vibrating Systems through Dynamic Structural Modification
Table 6
Test-case 2: original and modified system design variables and constraints.
| Parameter | Value | Modification bounds | Modified system without robustness (method [22]) | Modified system with robustness (proposed method) |
| m3 (kg) | 8.214 | [0; 1.080] | 8.761 | 8.744 | m4 (kg) | 2.609 | [0; 1.080] | 3.213 | 3.582 | (Nm−1) | 94.26e3 | [0; 144.9e3] | 98.44e3 | 207.51e3 | (Nm−1) | 94.26e3 | [0; 144.9e3] | 99.85e3 | 105.25e3 | k34 (Nm−1) | 75.47e3 | [0; 144.9e3] | 75.90e3 | 79.91e3 | k45 (Nm−1) | 83.40e3 | [0; 144.9e3] | 85.27e3 | 89.18e3 |
|
|