Research Article

Research on Damping Engagement Methodology in Dynamic Analysis of Isolated Structure

Table 4

Frequency of the experimental system.

NonisolatedIsolated
Measured (Hz)Theoretical (Hz)Error (%)Measured (Hz)Theoretical (Hz)Error (%)

13.914.3511.401.741.66−4.79
211.6912.204.327.057.8311.02
318.2017.63−3.1313.7413.941.45
4///18.9318.09−4.47

Error = (theoretical − measured)/measured.