Research Article
Optimal Design of Diversion Piers of Lateral Intake Pumping Station Based on Orthogonal Test
Table 2
Test plan and calculation results.
| Test plan | A | B | C | D | E (error) | Flow rate uniformity (%) | Weighted average angle (°) |
| 1 | 1 | 1 | 1 | 1 | 1 | 84.46 | 70.51 | 2 | 1 | 2 | 2 | 2 | 2 | 85.12 | 71.44 | 3 | 1 | 3 | 3 | 3 | 3 | 86.77 | 72.65 | 4 | 1 | 4 | 4 | 4 | 4 | 90.75 | 72.24 | 5 | 2 | 1 | 2 | 3 | 4 | 85.02 | 71.68 | 6 | 2 | 2 | 1 | 4 | 3 | 87.23 | 73.28 | 7 | 2 | 3 | 4 | 1 | 2 | 84.35 | 70.10 | 8 | 2 | 4 | 3 | 2 | 1 | 85.45 | 71.54 | 9 | 3 | 1 | 3 | 4 | 2 | 85.16 | 71.93 | 10 | 3 | 2 | 4 | 3 | 1 | 86.02 | 71.60 | 11 | 3 | 3 | 1 | 2 | 4 | 85.88 | 72.97 | 12 | 3 | 4 | 2 | 1 | 3 | 85.28 | 71.23 | 13 | 4 | 1 | 4 | 2 | 3 | 84.15 | 70.24 | 14 | 4 | 2 | 3 | 1 | 4 | 84.18 | 70.39 | 15 | 4 | 3 | 2 | 4 | 1 | 88.06 | 73.70 | 16 | 4 | 4 | 1 | 3 | 2 | 87.41 | 74.09 | K1 | 347.10 | 338.79 | 344.98 | 338.27 | 343.99 | | | K2 | 342.05 | 342.55 | 343.48 | 340.60 | 342.04 | K3 | 342.34 | 345.06 | 341.56 | 345.22 | 343.43 | K4 | 343.80 | 348.89 | 345.27 | 351.20 | 345.83 | k1 | 86.77 | 84.70 | 86.24 | 84.57 | 86.00 | | | k2 | 85.51 | 85.64 | 85.87 | 85.15 | 85.51 | k3 | 85.58 | 86.26 | 85.39 | 86.31 | 85.86 | k4 | 85.95 | 87.22 | 86.32 | 87.80 | 86.46 | Rj | 1.26 | 2.53 | 0.93 | 3.23 | 0.95 |
|
|