Research Article

Vibration Images-Driven Fault Diagnosis Based on CNN and Transfer Learning of Rolling Bearing under Strong Noise

Table 11

Summary of test results.

SNR (db)ParametersEPIMFASPCIGTMAverage

22Freezing typeHIIH
Test accuracy99.58%97.75%96.67%91.6796.42%
Time cost (s)161.52179.44194.86165.77175.40

16Freezing typeBBGF
Test accuracy97.92%90.42%83.33%76.67%87.09%
Time cost (s)170.68171.54194.14181.55179.48
Relative reduction rate1.67%7.50%13.80%16.36%9.68%

10Freezing typeFFBG
Test accuracy96.67%78.33%86.67%59.58%80.31 %
Time cost (s)170.46165.36194.19175.27176.32
Relative reduction rate1.28%13.37%-4.01%22.29%7.78%