Research Article

Encapsulation Based Method for Natural Frequency Identification of Deployable Solar Arrays with Multiple Plates

Table 8

Modal test results and corrected natural frequency of the simulant.

ConditionFirst-order natural frequency
Horizontal directionVertical direction

Theoretical value (Hz)0.8075.474
Test relative error (%)0.74−1.13
Corrected value (Hz)0.8065.510