Research Article

Experimental Research on Damping Effect of Double-Layer Tuned Mass Damper for High-Rise Structure

Table 3

Comparison of the dynamic characteristics of the model.

FrequencyFEA value (Hz)Theory value (Hz)Test value (Hz)Deviation rate (%)
(FEA-theory)/theory(Test-FEA)/FEA

ω11.7301.8701.6407.505.20
ω29.81010.1709.2003.506.20
ω318.03018.95016.4904.908.50