Research Article

Numerical Analysis of Dynamic Characteristics of Thermowell Based on Two-Way Thermo-Fluid-Solid Coupling

Table 3

Grid independence verification.

The number of meshes/ten thousand6397132209311

Outlet flow/kg/s0.6140.6290.6510.6500.649