Ventilation parameters of inlet and outlet in return airway.
| Outburst pressure (MPa) | Inlet | Outlet | Velocity magnitude (ms−1) | CH4 (%) | Pressure (Pa) | Velocity magnitude (ms−1) | CH4 (%) | Pressure (Pa) |
| 0 | 1.07 | 0 | 6 | 1.62 | 0 | −12 | 0.1001 | −1.38 | 78.89 | 7 | 3.10 | 77.93 | −11 | 0.1005 | −4.65 | 90.64 | 13 | 5.72 | 90.67 | −3 | 0.101 | −7.00 | 92.63 | 22 | 7.91 | 93.58 | 7 | 0.105 | −16.72 | 95.67 | 99 | 17.72 | 97.27 | 90 | 0.11 | −24.15 | 96.68 | 198 | 25.36 | 97.82 | 198 | 0.15 | −55.75 | 97.99 | 1025 | 58.07 | 98.5 | 1092 | 0.2 | −80.07 | 98.29 | 2104 | 83.49 | 98.66 | 2271 | 0.5 | −170.00 | 98.67 | 9450 | 177.54 | 98.84 | 10305 | 0.74 | −226.95 | 98.75 | 16829 | 236.41 | 98.88 | 18275 | 1 | −284.44 | 98.80 | 26422 | 297.38 | 98.99 | 28914 | 5 | −2142.67 | 98.97 | 1496880 | 2255.34 | 98.99 | 1659410 |
|
|