Research Article

The Airflow Reversal Law in Ventilation System after Coal and Gas Outburst in Tunneling Roadway

Table 2

Ventilation parameters of inlet and outlet in return airway.

Outburst pressure (MPa)InletOutlet
Velocity magnitude (ms−1)CH4 (%)Pressure (Pa)Velocity magnitude (ms−1)CH4 (%)Pressure (Pa)

01.07061.620−12
0.1001−1.3878.8973.1077.93−11
0.1005−4.6590.64135.7290.67−3
0.101−7.0092.63227.9193.587
0.105−16.7295.679917.7297.2790
0.11−24.1596.6819825.3697.82198
0.15−55.7597.99102558.0798.51092
0.2−80.0798.29210483.4998.662271
0.5−170.0098.679450177.5498.8410305
0.74−226.9598.7516829236.4198.8818275
1−284.4498.8026422297.3898.9928914
5−2142.6798.9714968802255.3498.991659410