Research Article

A New Joint Denoising Algorithm for High-G Calibration of MEMS Accelerometer Based on VMD-PE-Wavelet Threshold

Table 4

Performance evaluation of different denoising algorithms in dynamic processing.

MethodsOriginal signalVMD-PE-waveletEMDWaveletVMD

Shock stageValue (V)0.0880.0850.0660.0450.060
Errors (%)ā€”3.42548.831.8
Vibration stageValue (V)0.2490.2480.1860.0130.213
Errors (%)ā€”0.425.394.714.4