Research Article

Rolling Bearing Fault Diagnosis Using Improved Deep Residual Shrinkage Networks

Table 3

Fault diagnosis results of the DRSN and IDRSN.

SNR (dB)DRSN (%)IDRSN (%) (0.001)IDRSN (%) (0.003)IDRSN (%) (0.01)IDRSN (%) (0.05)IDRSN (%) (0.075)IDRSN (%) (0.1)IDRSN (%) (0.2)

āˆ’485.885.582.983.582.686.084.386.7
āˆ’286.888.887.585.790.288.590.590.0
091.390.992.190.691.189.591.190.5
293.192.791.091.792.994.593.493.1
493.295.595.392.492.793.294.893.4
694.395.994.396.593.894.895.894.8