Research Article

Rolling Bearing Fault Diagnosis Using Improved Deep Residual Shrinkage Networks

Table 4

Fault diagnosing accuracy results of the normalized DRSN and normalized IDRSN.

SNR (dB)DRSN (%)IDRSN (%) (0.001)IDRSN (%) (0.003)IDRSN (%) (0.01)IDRSN (%) (0.05)IDRSN (%) (0.075)IDRSN (%) (0.1)IDRSN (%) (0.2)

āˆ’487.692.090.890.493.484.388.590.4
āˆ’293.893.392.287.694.993.592.691.0
092.696.895.491.495.595.193.594.5
298.195.798.198.498.196.596.297.3
499.398.997.499.797.499.498.399.3
699.598.199.699.399.299.899.899.1